XP1000 NT4 – EV6

Field Change Order Instructions

Order Number: 00-XP1000 F001

This Field Change Order (FCO) addresses a system hang issue occurring on Compaq Professional Workstations XP1000 configured with EV6 V2.3 chips when running Windows NT4.0 Service Pack 4 or 5.

Key Information

  • Problem: Incompatibility between EV6 V2.3 chips and Windows NT4.0 (SP4/SP5).
  • Solution: Upgrade to the new EV6 V2.4 chip by replacing the system board.
  • Required Part: FCO Kit EQ-01769-01 (includes the V2.4 system board, update floppy, and necessary software).

Installation Highlights

  • Mean Time to Install: 30 minutes.
  • Safety: Always follow ESD precautions and allow 2 minutes after powering off for components to cool.
  • Software: The HAL/PAL and AlphaBIOS firmware must be updated using the provided floppy disk in the specific order instructed to ensure the system boots correctly.
00-XP1000 F001
December 2000
4 pages
Quality

Original
0.1MB