PDP-8/E Instruction Test 2

Order Number: MAINDEC-8E-D0BB

This document provides the technical details for the PDP-8/E Instruction Test 2 (Product Code: MAINDEC-8E-D0BB). The test is designed to verify the correct operation of key CPU functions including:

  • Autoindexing
  • Indirect Addressing
  • DCA (Deposit and Clear Accumulator) instruction
  • Interrupt and Processor IOT instructions (AND, TAD, ISZ, JMS, JMP)

The guide includes procedures for loading and running the diagnostic, instructions for operator action upon detecting errors, and a comprehensive listing of the test routines and individual test cases performed.

MAINDEC-8E-D0BB
2000
58 pages
Quality

Original
1.5MB