This engineering specification details the installation, inspection, and acceptance procedures for the KM8-A option board. It includes:
- Installation Procedure: Step-by-step instructions for installing the board in the Omnibus slot, setting switches as required by the diagnostic, and configuring power settings.
- Inspection: Procedures for checking hardware against shipping lists and ensuring components are free from damage.
- Acceptance Procedure: Performance requirements based on memory capacity (4K R/W memory) and specific diagnostic program tests for the KM8-A option.
- Component Documentation: Includes a detailed parts list, etch board layout, semiconductor conversion chart, and functional switch setting diagrams for different variations (15BA2/159A2 and 465A2/469A2 ROMs).