This document is a 1973 Engineering Change Order (ECO) for the G8000 filter network used in the PDP-11 family of processors. It addresses a technical issue where the voltage ratings of capacitors C1, C2, and C3 were insufficient. The correction specifies increasing these ratings from 15 volts to 20 volts. The document outlines both in-plant and field implementation procedures, noting that the repair takes approximately 0.5 hours to install and test.