Field Change Order

Field Change Order

Order Number: TU77A-M0007

This Field Change Order (FCO) TU77A-M0007 provides comprehensive instructions for retrofitting the TU77A magnetic tape transport. The document includes:

  • Applicability: Specifically targets various serial numbers and hardware configurations, including those requiring control module exchanges or noise reduction/heat exchanger kits.
  • Problem Symptoms: Addresses issues such as capstan wraps, media damage, tape stretch at unload, and general noise levels.
  • Installation Procedures: Detailed, step-by-step instructions for four separate kits (Kit I through IV), covering the replacement of control modules, installation of switch assemblies, and integration of cooling/acoustic components.
  • Parts List: A complete breakdown of parts required for each installation kit, including part numbers and quantities.
  • Figures: Technical diagrams depicting the installation of switch assemblies, decal placement, and component mounting.
  • Tech Tips: Includes several technical tips related to TU77 maintenance, such as cartridge opener motor replacement, interconnect board replacements, reel hub changes, and various troubleshooting adjustments.
TU77A-M0007
September 1981
78 pages
Quality

Original
3.9MB