The Instruction Test is a set of sixteen programs (octally numbered 1-20) used to verify the operation of PDP-1 instructions, excluding the IOT group. It includes a RIM loader to facilitate the loading of programs. The document details the operating procedures, including sense switch settings, load sequences, and error handling for each individual program (Programs 1 through 20). It also provides diagnostic flowcharts and program listings for each test.