This manual, dated May 1976, provides preliminary technical information for the DMC11 synchronous line unit. It is intended to assist technicians in installation, checkout, and maintenance procedures. The document covers four models: the remote units (DMC11-DA and DMC11-FA, using the M8201 module) and the local units (DMC11-MA and DMC11-MD, using the M8202 module).
Key sections include: - Introduction: General description of the units, operating modes (DDCMP and Bit Stuff), and cyclic redundancy checking (CRC) theory. - Installation: Step-by-step procedures for unpacking, jumper/switch configurations, and cabling for both remote modems and local links. - Programming: Detailed descriptions of registers, including data silos, control registers, and status registers. - Detailed Description: Functional and logical breakdowns of the transmission and reception paths, including timing and ROM configurations. - Maintenance: Philosophy, equipment required, and procedures for both preventive and corrective tasks.